×
Home
Segment
Agriculture & Irrigation
6" Stainless Steel Submerisble Pump
6" Water Filled Submerisble Motors
Centrifugal Three Phas
e
Endsuction Pumps
Residential
4" Engineering Grade Plastic Submersible Pumps
4" Oil Filled Submerisble Motors
Peripheral Booster Pumps
Jet Booster Pumps
Centrifugal Single Phase
VFD Pressure Booster System
Dewatering & Drainage Pumps
Industrial
Sewage Pumps
Commercial & Building Services
Vertical Multistage Pumps
Product
Shipping & Return
About Us
0
0
Sign in
Contact Us
Show categories
All Products
Pumps and Motors
Borehole Submersible Pumps
4'' Engineering Grade Plastic Submersible Pumps
CRI
DAB
Hydraulic Part - Wet End Only
WATERPACK
Borehole Combo (Pump Motor & Control Box)
VANSAN
6'' Stainless Steel Submersible Pumps
CRI
S6S- 14
S6S- 18
S6S- 22
S6S- 30
S6S- 48
S6S- 60
S6S- 76
S6S- 92
VANSAN
VSP 6010
VSP 6017
VSP 6030
VSP 6045
VSP 6060
VSP 6090
Borehole Submersible Motors
4" Oil Filled Submerisble Motors
CRI
230V 1P
CONTROL BOX
380V - 415V 3P
DAB
230V 1P
400V 3P
VANSAN
230V 1P
400V 3P
CONTROL BOX
6" Water Filled Submerisble Motors
CRI
VANSAN
DAB
Peripheral Booster Pumps
CRI
DAB
VANSAN - JOHNTECH
Jet Booster Pumps
CRI
VANSAN - JOHNTECH
DAB
Centrifugal Pumps
Single Phase
CRI
VANSAN
DAB
Three Phase
CRI
CTC-32
CTC-40
CTC-50
CTC-65
CTC-80
DAB
VANSAN
Twin Impeller
CM32
CM50
CM65
CM80
Vertical Multistage Pumps
CRI
MVS-1
MVS-2
MVS-3
MVS-4
MVS-5
MVS-10
MVS-15
MVS-20
DAB
VANSAN
SVM 1
SVM 2
SVM 3
SVM 4
SVM 5
SVM 8
SVM 10
SVM 12
SVM 15
VFD Pressure Booster Systems
CRI
DAB
Endsuction Pumps
CRI
ECW - 32
ECW - 40
ECW - 50
ECW - 65
ECW - 80
Submersible Pumps
Dewatering & Drainage Pumps
CRI
MP Series
DL Series
VANSAN
DAB
Sewage Pumps
CRI
SL Series
230V - 1PH
415V - 3PH
SL - 2V Series
230V - 1PH
415V - 3PH
Cutter Pumps CI
230V - 1PH
230V - 1PH
415 V - 3PH
DAB
Feka FXV
Feka FXC
Grinder FX
Pump Acessories
Pump Couplings & Spacers
Safety Ropes
Borehole base plate
Pressure Vessels
Membranes
Electronic Pressure Switch
Mechanical Switch
Hose connector
5 Way connector
Control panel
Single Phase
Three Phase
Valves & Fittings
RSV
Wedge Gate Valves
Butterfly Valves
Knife Gate Valves
Check Valves
Strainer and Foot valves
Ball Valve
Air Valve
Expansion Joints (Rubber bellow)
Pipes & Fittings
PVC Pipe Fittings
Blue Epoxy Coated LM6 Aluminium
Black Bitumen Coated Cast Iron
Fabricated Fittings
Grey Modulated PVC Fittings
Flanges & JIS
Quick Coupling Fittings
Quick Fitting
Latch
All Back System
Bauer
Wahl Above Ground
Perrot
Malleable & Multi Range Fittings
Multi Range
Malleable
Camlock Fittings
Polyprop
Type A
Type B
Type C
Type D
Type E
Type F
Type DC
Type DP
Aluminium
Type A
Type B
Type C
Type D
Type E
Type F
Type DC
Type DP
Rubber
Clamps
Compression Fittings
Coupling
Male Adaptors
Reducing Coupling
Elbow 90 Deg
Female Adaptor
Male Elbow 90 Deg
End Cap
Reducing Tee
Male Tee
Increasing Tee
Equal Tee
Female Elbow 90 Deg
Female Tee
Flanged Adaptor (T1600)
Single Union Ball Valve
O-Ring
Blocking Busk
Clinch Ring
Nut only
Saddles
Clamp Saddle
Reinforced Clamp
O-Ring
Tank Connectors
Brass Fittings and Accessories
Brass
Welder Machine
Generator
Public Pricelist
Public Pricelist
Sort By:
Featured
Price - Low to High
Price - High to Low
Newest arrivals
Name
K 80/300 T - IE3 / 7,5 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 70/300 T IE3 / 5,5 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 90/100 T IE2 / 4 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 66/100 T IE2 / 3 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 55/100 T IE2 / 2,2 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 40/100 230/400/50T IE3 / 1,8 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 40/100M / 1,8 KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
K 35/100 230/400/50T IE3 / 1,1 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 35/100 M / 1,1 KW / Fastline
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 55/50 M / 1,8 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 45/50 M / 1,1 KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 35/40 M / 0,75KW
Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels.
Suitable for sprinkler systems and other general water supply uses.
Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C.
K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
K 35/100M AUTO FASTLINE / 1,10KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
K 30/70M AUTO FASTLINE / 0,75KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
K 20/41M AUTO FASTLINE / 0,37KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
K 36/200 M; 2,2 KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
K 12/200 M; 0,75 KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
K 36/100 M; 1.8 KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
K 30/100 M; 1.1 KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
K 30/70 M; 0,75KW
Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses.
Operating range: from 1,8 to 96 m3/h, with head up to 62 metres.
Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa)
Installation: horizontal or vertical position, provided that the motor is always above the pump.
Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C.
Remainder of the range: from -15 °C to +110 °C.
Prev
33
34
35
36
37
38
39
Next